Masonry Magazine February 2009 Page. 24
MOISTURE MANAGEMENT
The wall cavity, which can be done in seconds. Since all of the moisture management components are built into each panel, contractors don't have to waste time ordering and then waiting for separate items to arrive on the jobsite.
"It's a big time and money saver," he says. "Contractors like it because there are no callbacks. Callbacks are horribly expensive. It is a total flashing system. We've taken components of traditional flashing and put them all together in a single panel." Besides cutting installation time, TotalFlash is almost foolproof to attach to walls, Bickett says.
"The idea is to reduce the opportunity for errors and omissions. The panel design takes the guess work out of installation. This is easier to put together right than to do it wrong," he says. "The opportunity for error is reduced."
Sandell's Douglas says the Air-Tight air barrier also offers fast installation. It can be brushed, rolled or sprayed into buildings quickly.
"I've seen the product go up on a dorm building in one day," Douglas says. "It's quick to apply."
Joining the Green Movement
THE BUILDING INDUSTRY as a whole is making a concerted effort to be more environmentally friendly. Moisture management companies are doing their part by offering products that contain recycled materials.
FILL BLOCK WALLS
WITHOUT A CONCRETE PUMP OR FORKLIFT
PumpMaster
Model PC-21
AIRPLACO
EQUIPMENT COMPANY
Call for your DVD!
Northeast
513.321.2850
1888.348.2950
Southeast
281.468.7102
1.866.468.7102
West
626.256.9310
1.888.383.8635
www.airplaco.com
CIRCLE 296 ON READER SERVICE CARD
22 MASONRY
SINCE 1946
February 2009 www.masoncontractors.org
Understanding
Water Repellent Primer
By Larry Kotke
First of all, let me address the difference between water repellents and waterproofers. Many people think the two terms are interchangeable, but they really aren't. Typically, waterproofers are thick, film-forming coatings. These types of coatings would often be used below grade, such as on a basement wall. As one example, we all have seen a new house under construction and the black coatings being applied to the exterior of basement walls. These coatings are meant to prevent water from entering the basement wall. They are high build (thick) applications that are meant to stop all movement of water and are not breathable (do not allow the movement of moisture vapor or moisture in a gaseous form). They are designed to stand up to soil and water's pressure against the outside of a basement wall. Another example is water's pressure in pools and fountains against their containment wall. This is referred to as hydrostatic pressure. Water repellents are not intended for use where they would be exposed to hydrostatic pressure. They simply cannot stand up to or resist that constant pressure being exerted on the surface. Water repellents are meant to repel rain and water over relatively short periods in comparison to below grade and pool or fountain situations.
The amount of water repellent in a product is measured by the products solids content and is noted as a percentage. For example, a siloxane water repellent may be designated as 7 percent, 10 percent, or 15 percent solids. Silanes are usually 20 percent or 40 percent because of the siliane's volatility. Acrylics can range from 7 percent to as much as 30 percent to 35 percent. The amount of solids required will be dictated by the porosity of the surface. A dense, hard, burnt-face brick will only need 7 percent solids water repellent, but an extremely porous split-face block would require 20 percent solids. When choosing a solids content, it is best to remember that more is not always better. Too high of a solids content on a dense brick can cause a significant reduction in the brick's moisture vapor transmission rate. This can lead to a build-up of moisture in the brick and mortar, which is undesirable.
Water repellents are generally divided into two groups: penetrating and film forming. Penetrating water repellents work by penetrating into the pore structure of the substrate and deposit their repellent component in and on the masonry's pores. They do not, as a rule, alter the appearance of the surface to which they are applied. Some of the most common penetrating types would be the silane, siloxane, silicates and silicones, or a blend of these repellents. They are well suited for application to both vertical and horizontal surfaces. These types of repellents are well suited for use on older, historically significant buildings, where altering of the surface appearance would be undesirable.
The film formers, which include acrylics, mineral gum waxes, silicone resins, stearates and urethanes, are the most common. They work by forming a film on the surface to which they are applied. Their moisture vapor transmission rates will not be as good as the penetrating types and, in some cases, such as the urethanes, will have virtually none. Some people like a glossy or wet look to the surface, so the acrylic type repellents would be the type of choice.
Larry Kotke is VP of operations for Diedrich Technologies Inc., a division of Sandell Construction Solutions. He can be reached at 800-323-3565.